| Specifications(Output current) | 100A | ||
| Input | Rated voltage | Single-phase 220VAC、Three-phase 380VAC、Three-phase 440VAC | |
| Input range | Rated voltage±15% | ||
| Input frequency | 45~65HZ | ||
| Efficiency | ≥87% | ||
| Maximum current | Single-phase 220 | <18A | |
| Three-phase 380 | <6A | ||
| Three-phase 440 | <6A | ||
| Output | Floating voltage | 26.4VDC±0.1V(Can be adjusted according to customer requirements and battery specifications) | |
| Average voltage | 28.2VDC±0.1V(Can be adjusted according to customer requirements and battery specifications) | ||
| Average floating charge conversion current | Rated output current10%±1A | ||
| Regulation accuracy | ±1% | ||
| Output ripple and noise | VPP≦300mV | ||
| Function | Alarm and protection functions | Input under voltage protection, input over voltage protection, output under voltage warning, output over voltage protection, output short circuit protection |
|
| Standard functions | Public warning, fault passive dry contact port (contact limit specification: 32V / 1A) | ||
| Optional functions | Remote power on / off, remote manual charging, remote manual equalization, standard Modbus-RTU485 communication, external battery temperature compensation, automatic battery identification function | ||
| Indication and adjustment | Input instructions, work instructions, fault instructions, current regulation | ||
| Working environment | Operating temperature | ‐15℃~+55℃ | |
| Storage temperature | ‐25℃~+85℃ | ||
| Relative humidity | 0~95%(Non-condensing) | ||
| Atmospheric pressure | 70kPa~106kPa | ||
| Cooling method | Air-cooled | ||
| Standard range | Safety | IEC61000-4-2、IEC61000-4-3、IEC61000-4-4、IEC61000-4-5、IEC61000-4-6、IEC60092-101、IEC60068-2-11 | |
| Conduction, radiation | CISPR16、EN55022 | ||
| Certification | CCS Type approval | ||
| Others | Size (WxDxH) mm | 105x147x180 | |
| Weight | 36kg | ||
| Installation method | Wall mount | ||